notch associated with the labeled velocity, and the dotted line represents the corresponding −20 dB point. (Bottom) Relative signal‐to‐noise improvement using different gauge lengths compared to a 5 m gauge.

      Two trends are easily observed: (1) larger gauge lengths can be used if the apparent velocities of interest are large, and (2) spectral notches are not as limiting on the upper frequencies for small gauges. It might appear that the conclusion should be to always use a small gauge length; but, as previously mentioned, the SNR improves as the gauge length increases (Figure 2.3, bottom). The vertical axis shows the SNR improvement as compared to a 5 m gauge, in dB; thus, the improvement using a 15 m gauge is 4.8 dB, while the 40 m gauge provides 9 dB improvement. Therefore, the goal is to use as large a gauge length as possible without damaging the desired frequency content of the seismic waves being recorded.

      2.4.2. Sampling Rate

      The IU sends a pulse of light into the fiber with a sampling rate of 10 kHz or higher. The time between these pulses are set so that the light has time to reach the end of the fiber and return as backscattered energy to the photodetector in the IU. The longer the sensing fiber, the slower this sampling rate should be, so that the pulse of light has the necessary time to return to the IU without interfering with another pulse.

      2.4.3 Pulse Width

image

      2.5.1. Fading

      The occurrence of fading changes in both time and distance along the fiber; for example, extremely small changes in the fiber’s temperature move the scattering sites and cause temporary dimming of the backscattered signal at new locations. It has been observed (Ellmauthaler et al., 2016) that approximately 3% of the fiber is faded at any given moment; for example, if the sensing fiber has 5,000 channels, that translates to as many as 150 channels exhibiting some form of fading. However, even during small time intervals of approximately 1 min, the fading on the affected channels will move. Thus, if it is possible to repeat the source and take multiple measurements, it is easy to obtain reliable data eventually without fading.

image