Continuous Emission Monitoring


Скачать книгу

CFR 60 Appendix A. Since a CEM system is not an EPA reference method, it has been argued that CEM system data cannot be used in enforcement cases. Also, early experience with CEM systems was somewhat less than satisfactory, and the lack of QA programs often made the CEM data less defensible in court. The conservative approach was to rely ultimately on the reference methods for enforcement issues.

      The use of CEM system data for enforcement has grown as confidence has increased in the quality of the data. Specifying in a permit that a CEM system is the compliance method also helps to eliminate any ambiguity regarding compliance determinations. The EPA programs developed in response to the volume of data available have matured from the use of CEM systems from compliance indicating systems to compliance monitoring systems.

      Compliance assurance monitoring (CAM) programs, the credible evidence rule, and periodic monitoring requirements for State Title V CAAA permits are also relevant to predictive and parameter monitoring methods, and fill in the monitoring gaps where CEM systems are not explicitly required (although CEM systems may still be used in such circumstances). As a result, EPA has put in place a regulatory framework that can be used to determine if a source is meeting its emission limits and standards at all times, as is required by the Clean Air Act of 1990.

      Compliance Indicating Systems – Using CEM Systems for Reporting Excess Emissions

      Federal CEM requirements were originally developed in 1975 to provide a means for sources and agencies to check the operation and performance of NSPS‐mandated control equipment such as bag houses and wet scrubbers. The intention was that the source could use the emissions data to track the control system performance, and that reports would be submitted quarterly to the agency. These reports, called excess emission reports (EERs), were to include data on the exceedances of emissions standards.

      1 To indicate if the source is using good operating and maintenance practices on its process and its control equipment to minimize emissions

      2 To provide the agency with data on upset conditions or trend data indicating degradation of control equipment performance

      3 To provide the agency with a continuous record of the source's ability to comply with standards

      4 To provide a screening tool in inspection targeting programs

      5 To provide the agency with sufficient data to issue a Notice of Violation (NOV) if the source is not complying with regulations or standards

      Under U.S. regulations when CEM data are used for excess emissions reporting, the data usually have not been used alone as legally enforceable determinants of emission exceedances. Instead, the data have been used to show that a problem exists and, based upon the severity of the problem, the agency takes further action, which might include conducting reference method tests for determining compliance with emissions standards. The reference method test data would then determine if the source was complying with its emissions standards.

      Using EER data to show that a system is not meeting emissions standards and then requiring an EPA compliance test to initiate legal action is cumbersome to some. The advantage, however, is that this method offers the agency significant negotiating power and provides flexibility in the enforcement program. The problem is that evaluating excess emission reports and following up with inspections and compliance tests can require more time and resources than an agency may have available.

      Until 1997, many states adopted the position that excess emission report (EER) data would not be used to refer cases to the Department of Justice or to issue an order of noncompliance, unless other regulatory mandates specify the CEM system as the compliance method (as a compliance indicating systems). Actually, this position has not precluded the use of EER data in enforcement cases. Because an agency may review all available information when evaluating the compliance status of a source, the CEM data can constitute part of the record of an enforcement proceeding. Section 113 of the Clean Air Act states:

      “Whenever, on the basis of any information available to him, the Administrator finds that any person is in violation of any standard of performance…he may bring a civil action in accordance with subsection 113(a).”

      EPA can use EER data alone, as a basis for issuing a “finding of violation” (FOV) or a “notice of violation” (NOV) (U.S. EPA – OAQPS, 1984, Reich). If the source does not come into compliance after an FOV or NOV is issued, EPA must acquire compliance test (Reference Method) data before it can initiate litigation or issue a Notice of Noncompliance (NON). However, NOVs have been issued using CEM data on the basis of the Clean Air Act Section 113(a) to effectively enforce source compliance (McCoy 1985, 1990).

      For agency personnel, a handbook providing procedures for reviewing excess emission reports is available (Quarles and Peeler 1986). A more recent review guideline, developed by the Commonwealth of Virginia Department of Air Quality (VADEQ), extends review procedures to predictive emission monitoring systems (PEMS) and continuous parametric monitoring systems (CPMS) as well as CEM systems (VADEQ 2018).

      Enforcement Levels

      The advantage of the “Excess Emission” (EER) approach for source enforcement is that it allows an agency discretion in its enforcement program. Based upon past source performance, agency resources, and so on, an agency may choose to follow up on or not to follow up on reported instances of excess emissions. A phone call may suffice to clarify a problem, an FOV or NOV may be issued, or, further, a site inspection or source test may become necessary.

      Depending on the stringency of the program, the action levels may vary. For example, percentages for acceptable out‐of‐compliance periods could be <1% (more stringent) or <3% (less stringent) instead of <2% as given in Table 2‐5. Acceptable monitor downtime (in the absence of a percent availability requirement in the facility permit) might be specified in an agency policy as <1% (more stringent) or <3% (less stringent).

       Level 1

      On the first level, the agency evaluates the facility's quarterly EERs, by checking the following items:

       Submittal timeliness and completeness

       Reports of periods and magnitudes of excess emissions

       Nature and cause of each period of excess emissionsTABLE 2‐5 Example Target Criteria and Agency Follow‐up Action Levels Based Upon a Review of the Excess Emission ReportAgency% of Time Compliance Response% of Monitor Out of ComplianceSuggested Downtime Follow‐upActionAcceptable<2.0%<2.0%If both cases exist, acknowledge receipt of EERRequest for corrective action>2.0% and <5.0%>2.0% and < 5.0%If either or both cases exist, then send a letter requesting corrective action within 30 daysWarning letter>5.0% and <10.0%>5.0% and < 10.0%If either or both cases exist, then warn by letter of unacceptable condition, request explanations of condition, and request corrective action plan to prevent condition from reoccurringNotice of violation>168 hrs >10%If either or both cases exist, then issue NOV and require performance (compliance) test for monitored pollutant, monitor certification (PS) tests and request corrective action plan to prevent condition from reoccurring

       Periods during which the continuous