Группа авторов

Emergency Medical Services


Скачать книгу

      The classic position for intubation has the patient supine at the level of the rescuer’s xiphoid. However, prehospital patients requiring airway management are often found in unusual positions, such as on the ground or floor. Conventional approaches to laryngoscopy and intubation must be modified in these scenarios.

      There are several approaches to rescuer positioning for ground‐level endotracheal intubation.

       Prone. The rescuer lies prone on the ground in line with the patient’s head (Figure 4.1). The rescuer places both elbows on the ground. With this approach, laryngoscopy requires lifting at the wrist rather than with the forearm. Placement of the tracheal tube must be accomplished using movements of the wrist.

       Left lateral decubitus position. With this approach, the rescuer lays on his or her left side, perpendicular to the head of the patient (Figure 4.2). As with the prone position, the rescuer stabilizes the left elbow on the ground, relying on wrist movement to perform laryngoscopy. However, the right arm is free to facilitate tube placement in a conventional fashion.

       Kneeling. The rescuer kneels at the patient’s head. The left elbow and forearm may be supported by the rescuer’s knee. In this position, the rescuer assumes a slightly more vertical position over the patient’s head, and thus the angle for glottis visualization may be steeper than usual (Figure 4.3).

       Sitting. The rescuer sits at the patient’s head with legs either crossed or extended to each side of the patient’s head. The left arm may be braced against the rescuer’s leg (if sitting with crossed legs) (Figure 4.4).

       Straddling the patient. The rescuer straddles the patient in a face‐to‐face position. The rescuer holds and inserts the laryngoscope with the right hand, and passes the tube with the left hand (Figure 4.5).

      Because EMS patients are frequently found and treated at ground level, clinicians should learn each of these techniques. Note that compared with traditional positioning, the rescuer’s face is closer to the patient’s oropharynx with ground‐level intubation, and thus visualization of glottic structures may differ from conventional approaches. (There may also be greater risk of exposure of the clinician to aerosolized respiratory secretions.) In some cases, tilting the patient upward by using the stretcher back or a backboard may improve airway visualization and access [1].

      Limited studies suggest that the position may result in higher intubation success rates than the other ground‐level techniques. When compared to kneeling with a simulated patient on the ground, the left lateral decubitus position provided better glottic exposure [2]. In actual patient situations, laryngoscopy difficulty was lower in this position: 11.1% versus 26.9% for the kneeling group. Subsequently, there were a higher number of intubation attempts in the kneeling position than for the left lateral decubitus position [3]. It may be a better position for three reasons: the operator has better visual alignment with the larynx in the left lateral decubitus position; the left forearm acts as a lever during exposure, which minimizes operator effort; and the right arm is completely free during the procedure for tube placement and suctioning [3].

Photo depicts prone intubation. Photo depicts left lateral decubitus intubating position.

Photo depicts kneeling intubation. Photo depicts sitting intubation. Photo depicts straddle intubation. Photo depicts face-to-face tomahawk intubation position.

      When face‐to‐face intubation is the only available option, the EMS clinician should evaluate whether immediate airway intervention or patient extrication is most appropriate. The estimated time of extraction combined with patient condition may influence the decision‐making process. High‐flow oxygen devices and supraglottic airways may provide suitable alternatives in these situations.

      Optimal lighting is important during airway procedures. Increased ambient lighting allows for better equipment preparation and procedure execution. However, EMS clinicians often need to perform airway interventions in suboptimal lighting conditions, such as at night, while conducting military operations, in a confined space rescue, or in indoor areas with poor lighting. A common pitfall of intubation is equipment failure resulting in suboptimal airway illumination; for example, broken laryngoscope bulbs, dead laryngoscope batteries, or damaged airway equipment. Regular equipment checks and use of protective carrying cases are essential aspects of practice. Spare bulbs and batteries should always be part of the standard airway kit. Simple procedures, such as rotating batteries