Группа авторов

Analytical Methods for Environmental Contaminants of Emerging Concern


Скачать книгу

AnalytesMatrixAnalytical methodAnalysis conditions156 target analytes screened120 satisfactorily determined71 and 73 compounds quantifiedWastewater and receiving waters in South AfricaUHPLC-Orbitrap MSESIOrbitrap analyserAnalytical column: XBridge™ C18, 100 mm × 2.1 mm, 3.5 μmMobile phase: [A] 0.1% formic acid in water and [B] 0.1% formic acid in acetonitrileElution programme: 0–2% B, progressed to 98% B in 15 minutes, then a hold in 2 minutes, and returned to the initial conditions[100]17-α-ethynylestradiol [EE2], 17-β-estradiol [E2], estrone [E1], testosterone, progesterone, diclofenac, primidoneTropical estuarine sedimentsLC-MS/MSESI[+]/[−] modesTriple quadrupole analyserAnalytical column: Kinetex XB C18, 30 mm × 2.1 mm, 1.7 μmMobile phase:for negative ionization mode [A] 0.2% NH4OH in 95% water [95 : 5, H2O:OS] [OS consists of 60% methanol and 40% acetonitrile] and [B] 0.2% NH4OH in 95% OS [95 : 5, OS: H2O]. for positive ionization mode [A] 95% water [95 : 5, H2O:OS] [OS] and [B] 95% OS [95 : 5, OS: H2O].Elution programme: for negative ionization mode 0 – 3 minutes 5% B progressed to 95% in 4 minutes and then holding it constant for 2 minutes and returned to the initial conditionsfor positive ionization mode 0–3 minutes 5% B progressed to 95% in 3 minutes and then holding it constant for 2 minutes and returned to the initial conditions[89]Ceftazidime, meropenem, amoxicillinCiprofloxacin, lincomycin, clindamycin, erythromycin, azithromycin, clarithromycin, tylosin, sulfamethazine, sulfamethoxazole, trimethoprim, tetracycline, minocyclinechlortetracycline, oxytetracyclinetriclosan, triclocarban, vancomycinchloramphenicolEnvironmental water samples [surface water, treated wastewater effluents]UHPLC -MS/MSESI [+]/[−] modesTriple quadrupole analyserAnalytical column: Poroshell 120EC-C18, 100 mm × 3.0 mm, 2.7 μmMobile phase: [A] 0.1% formic acid in water and [B] 0.1% formic acid in a 50 : 50 [v/v] mixture of methanol and acetonitrileElution programme: 0–1.5 minutes 10% B progressed to 90% B at 15 minutes, held until 22 minutes, and returned to the initial conditions[87]40 multiclass antibiotics from cephalosporin, fluoroquinolone, lincosamide, macrolide,nitroimidazole, quinolone, sulfonamide and tetracycline groupsEnvironmental matricesLC-MS/MSIon source: ESITriple quadrupole/linear ion trap analyserAnalytical column: Kinetex C18, 100 mm × 2.1 mm, 2.6 μmMobile phase: [A] 0.001% formic acid in water and [B] methanolElution programme: 0–0.01 minutes 5% B progressed to 10% B at 3.0 minutes, then to 28% B at 6.0 minutes, 70% B at 11.0 minutes, 85% B at 13 minutes, and finally returned to the initial conditions[88]acetaminophen, acetazolamide, acetylsalicylic acid, amiodarone, amoxicillin, ampicillin, atenolol, azithromycin, caffeine, carbamazepine, ciprofloxacin, diclofenac, clarithromycin, cyclophosphamide, erythromycin A, flumequine, gemfibrozil, hydrochlorothiazide, ibuprofen, josamycin, ketoprofen, lorazepam, losartan, metoprolol, metronidazole, niflumic acid, nordiazepam, 19-norethindrone, norfloxacin, ofloxacin, oxazepam, oxolinic acid, phenazone, piperacillin, roxithromycin, spiramycin, sulfadiazine, sulfamethazine, tylosine sulfamethoxazole, tetracycline, trimethoprimThree fish species hake [Merluccius merluccius], red mullet [Mullus surmuletus], sole [Solea solea] and one crustacean species shrimp [Palaemon serratus]UPLC-MS/MSIon source: ESI[+]/[−]Triple quadrupole analyserAnalytical column: C18 Acquity UPLC HSS T3, 50 mm × 2.1 mm, 1.8 μmMobile phase:for positive ionization mode [A] 0.1% formic acid in water and [B] acetonitrilefor negative ionization mode [A] 0.01% formic acid and eluent [B] acetonitrileElution programme: 0–2 minutes 2% [B] progressed to 60% at 4 minutes, then to 100% at 6 minutes, held 1 minute and returned to the initial conditions[92]56 antimicrobial drugs (tetracyclines, sulfonamides,β-lactams, macrolides and quinolones)Wastewater and sea waterUPLC-MS/MSIon source: ESI[+]Triple quadrupole analyserAnalytical column: ACQUITY UPLC®BEH C18 column [100 mm × 2.1 mm] with a 1.7 μm particle sizeMobile phase: [A] 0.1% formic acid in water and [B] acetonitrileElution programme: 0 minutes – 1% B at progressed to 99% B at 10 minutes and then returned to the initial conditions[95]

      1 1 Roig, B. and D’Aco, V. (2016). Distribution of pharmaceutical residues in the environment. In: Pharmaceuticals in the Environment, 1st edn (ed., R.E. Hester and R.M. Harrison), 34–69. Cambridge: Royal Society of Chemistry. doi: 10.1039/9781782622345.

      2 2 Kümmerer, K. (2008). Pharmaceuticals in the environment – a brief summary. In: Pharmaceuticals