Doughty, T.E. Neal, and H.L. Floyd, II, “Predicting incident energy to better manage the electric arc hazard on 600-V power distribution systems,” IEEE Trans. Ind. Appl., vol. 36, no. 1, pp. 257–269, Jan./Feb. 2000.
15 R.A. Jones, D.P. Liggett, M. Capelli-Schellpfeffer, T. Macalady, L.F. Saunders, R.E. Downey, L.B. McClung, A. Smith, S. Jamil, and V.J. Saporita, “Staged tests to increase awareness of arc-flash hazards in electrical equipment,” IEEE Trans. Ind. Appl., vol. 36, no. 2, pp. 659–667, March/April 2000.
16 R. Wilkins, M. Lang, and M. Allison, “Effect of insulating barriers in arc flash testing,” in conf. record, IEEE Pulp and Paper Industry Technical Conf. pp. 120–125, Seattle, 2008.
17 NFPA 70E, Electrical Safety in Workplace, 2012.
18 M.G. Drouet and F. Nadeau, “Pressure waves due to arcing faults in a substation,” IEEE Trans. PAS, vol. PAS-98, no. 5, pp. 1632–1635, Sep. 1979.
19 M. Wactor, G.H. Miller, J. Bowen, and M. Capelli-Schellpfeffer, “Modeling of pressure wave associated with arc fault,” IEEE PCIC conf. Rec., pp. 333–341, Sept. 2000.
20 T.E. Neal and R.E. Parry, “Sharpnel, pressure and noise,” IEEE Industry Applications Magazine, vol. 11, no. 3, 49–54, June 2005.
21 IEEE Std. 80, Safety in AC Substation Grounding, 2000.
22 L.A. Geddes and L.E. Baker, “Response of passage of electrical current through the body,” J. Assoc. Adv. Med. Instrum., vol. 2, pp. 13–18, Feb. 1971.
23 IEC 604791-1, Effect of Current on Human Beings and Livestock Part 1: General Aspects, 2005.
24 C.F. Dalziel, J.B. Lagen, and J.L. Thruston, “Electrical shock,” AIEEE Trans. PAS, vol. 60, pp. 1073–1079, 1941.
25 C.F. Dalziel and R.W. Lee, “Lethal electric currents,” IEEE Spectrum, pp. 44–50, Feb. 1969.
26 L.P. Fewrris, B.G. King, P.W. Spence, and H. Williams, “Effect of electrical shock on the Heart,” AIEEE Trans. PAS, vol. 55, pp. 498–515 and 1263, May 1936.
27 U.G. Biegelmeier and W.R. Lee, “New considerations on the threshold of ventricular fibrillation for AC shocks at 50–60 Hz,” Proc. IEEE, vol. 127, pp. 103–110, 1980.
28 W.B. Kouwenhoven, et al., “AC shocks of varying parameters affecting the heart,” AIEEE Trans. PAS, vol. 78, part 1, pp. 163–169, 1959.
29 D. Roberts, “50-V shock hazard threshold,” IEEE Trans. Ind. Appl., vol. 46, no. 1, pp. 102–107, Jan./Feb. 2010.
30 Society of Fire Protection Engineers (SPFE) Task Force, Engineering Guide to Predicting First and Second Degree Skin Burns, Boston, MA, 2000.
31 NFPA 921, Guide for Fire and Explosion Investigations, 2011.
32 ANSI/IEEE C2, National Electric Safety Code, 2007.
33 IEEE 1584a, IEEE Guide for Performing Arc-Flash Hazard Calculations—Amendment 1, 2004.
34 IEEE P1584b/D2, Draft 2, Guide for Performing Arc Flash Hazard Calculations—Amendment, July 2009 (unapproved).
35 ASTM F1506, Specifications for Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Electrical Arc and Related Thermal Hazards, 1998.
36 J.C. Das, “Design aspects of industrial distribution systems to limit arc flash hazard: Part II-Analysis,” IEEE Trans. Ind. Appl., vol. 41, no. 6, pp. 1467–1482, Nov./Dec. 2005.
37 J.C. Cawley and T. Homce, “Trends in electrical injury in the U.S., 1992–2002,” IEEE Transactions on Industry Applications, vol. 44, no. 4, pp. 962–972, July/August 2008.
38 J.C. Cawley and B.C. Brenner, “Occupational electrical injuries in the U.S., 2003–2009,” IEEE Paper No. ESW-2012-24, 2012.
Конец ознакомительного фрагмента.
Текст предоставлен ООО «ЛитРес».
Прочитайте эту книгу целиком, купив полную легальную версию на ЛитРес.
Безопасно оплатить книгу можно банковской картой Visa, MasterCard, Maestro, со счета мобильного телефона, с платежного терминала, в салоне МТС или Связной, через PayPal, WebMoney, Яндекс.Деньги, QIWI Кошелек, бонусными картами или другим удобным Вам способом.