Группа авторов

Energy Storage


Скачать книгу

direct or indirect storage systems.

       1.3.1.1 Active Two-Tank Direct

Schematic illustration of active two-tank direct thermal energy storage.

      1.3.1.1.1 Active Two-Tank Indirect

      In two-tank indirect systems, different fluids are used as the HTF and storage material. In cases when HTF is expensive or HTF is not well suited to be used as storage materials, such a system can be implemented. The storage material from the low-temperature storage tank flows through an extra heat exchanger. The fluid is heated by the high-temperature HTF in the heat exchanger. The high-temperature storage material then returns back to the high-temperature storage tank. The HTF exits the heat exchanger at a low temperature returning to the receiver system to absorb heat again to continue the cycle. As observed in a two-tank direct system, storage material from the high-temperature tank is further used to generate steam. In contrast to the direct system, an extra heat exchanger is needed in an indirect system, making this system costlier.



Parabolic trough CSP projects Thermal energy storage (TES) Thermal energy storage capacity Storage description and material
Airlight Energy Ait-Baha Pilot Plant Packed bed 5 hour(s) Packed-bed of rocks
Andasol-1 (AS-1) 2-tank indirect 7.5 hour(s) Molten salt 60% sodium nitrate and 40% potassium nitrate.
Andasol-2 (AS-2) 2-tank indirect 7.5 hour(s) Molten salt 60% sodium nitrate and 40% potassium nitrate.
Andasol-3 (AS-3) 2-tank indirect 7.5 hours Molten salts
Archimede 2-tank direct 8 hour(s) Molten salt 60% sodium nitrate and 40% potassium nitrate.
Arcosol 50 (Valle 1) 2-tank indirect 7.5 hour(s) Molten salt 60% sodium nitrate and 40% potassium nitrate.
Arenales 2-tank indirect 7 hours Molten salt 60% sodium nitrate and 40% potassium nitrate.
ASE Demo Plant 2-tank direct 4.27 MWh-t Molten salt
Ashalim (Negev) 2-tank indirect 4.5 hours Molten salts
2-tank indirect 8 Hours Molten salts 60% sodium nitrate and 40% potassium nitrate
Aste 1B 2-tank indirect 8 Hours Molten salts 60% sodium nitrate and 40% potassium nitrate
Astexol II 2-tank indirect 8 Hours Molten salt 60% sodium nitrate and 40% potassium nitrate
Bokpoort 2-tank indirect 9.3 hours Molten salt
Casablanca 2-tank indirect 7.5 hours Molten salt 60% sodium nitrate and 40% potassium nitrate.
Chabei 64MW Molten Salt Parabolic Trough project 2-tank direct 16 hours Molten salt
Delingha 50MW Thermal Oil Parabolic Trough project 2-tank indirect 9 hours Molten salt
DEWA CSP Trough Project 2-tank indirect 15 hours Molten salt
2-tank indirect 4 hours Molten Salt
Extresol-1 (EX-1) 2-tank indirect 7.5 hour(s) Molten salt 60% sodium nitrate and 40% potassium nitrate.